人妻巨大乳一二三区,CHINESE熟女老太HD,色偷偷伊人大杳蕉综合网,热RE99久久精品国产99热

全國服務(wù)咨詢熱線:

15618996225

當(dāng)前位置:首頁  >  產(chǎn)品中心  >  太赫茲  >  太赫茲功率計(jì)  >  Mm-Wave power meter高靈敏度毫米波功率計(jì)

高靈敏度毫米波功率計(jì)

簡要描述:高靈敏度毫米波功率計(jì)Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產(chǎn)品型號(hào):Mm-Wave power meter
  • 更新時(shí)間:2024-09-02
  • 訪  問  量:774

產(chǎn)品簡介

品牌其他品牌產(chǎn)地類別進(jìn)口
應(yīng)用領(lǐng)域農(nóng)業(yè),電子,汽車,電氣

詳細(xì)介紹

 

高靈敏度毫米波功率計(jì)Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計(jì)Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

全國統(tǒng)一服務(wù)電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區(qū)劍川路955號(hào)707-709室

業(yè)務(wù)咨詢微信

99精品国产在热2019| 高潮AAA人人爽人人爱| 女人和拘做受A级毛片视频| 国产精品毛片一区二区三区| 女人脱精光直播APP| 久久亚洲精品中文字幕| 成人免费视频| 人妻人人澡人人添人人爽| 交换娇妻系列38部分阅读| 蜜臀AV夜夜澡人人爽人人| 小雪被老汉各种姿势玩弄| 国产又色又爽又高潮免费| 亚洲中久无码永久在线观看同| 中文字幕乱偷无码AV蜜桃| 欧洲熟妇色xxxxx欧美老妇伦 | 中文字幕一区二区人妻| 无码日韩精品一区二区免费暖暖| 无码国产精品一区二区免费式直播| 久久久777天天躁狠狠躁AV| 国产成人无码精品久久久影院| 亚洲内射少妇AV影院| 狠狠躁夜夜躁人人爽超碰97香蕉 | 门卫老头吸允校花奶头| 西西GOGO顶级艺术人像摄影 | 欧美成人一区二免费视频| 99精品国产兔费观看久久99 | 国产精品久久国产精麻豆99网站 | 两个领导在车里吃我奶| 人妻用嘴含精大口吞精| 野花香高清视频在线观看免费| 班长撕开乳罩揉我胸好爽 | 竹菊精品久久久久久久99蜜桃 | 巨胸爆乳美女露双奶头挤奶| 亚洲久热无码AV中文字幕| 97久久精品午夜一区二区| 久久精品国产亚洲AV香蕉| 亚洲成A人V欧美综合天堂麻豆| 少妇BBW搡BBBB搡BBBB| 亚洲色精品三区二区一区| VIDEOS日本多毛HD护士| 啊灬啊灬啊灬快灬A片免费 |